Choose a location for your VTAP reader
Position the VTAP50 and VTAP100 so that users can easily tap their smartphone against the top of the device
CAUTION: Never allow a metal surface between the VTAP reader and the user's phone or card.
The square case for a VTAP100-PAC-W is 86mm x 86mm and 25.5mm deep.
The compact case for a VTAP100 is 97mm x 49mm and 40mm deep.
The VTAP reader must be stored and operated under the following conditions:
-
Ambient temperature -25 to +70°C (-13 to 158°F)
-
Humidity 0 to 95% RH non-condensing
-
Pressure 86-106kPa
The VTAP100-USB reader is designed for indoor use only.
The
The VTAP100-PAC-485 reader can be used indoors or outdoors.
When using the -CC model outdoors, install the VTAP reader in a wallmount (vertical) orientation, in as sheltered a location as possible. The case is not sealed because the design allows for water ingress and egress. Do not block the drain holes in the case. The PCBs for this model are conformally coated to protect the electronics.
The compact case separates into two pieces, which clip together around the PCB. After deciding where you will use your VTAP reader, you may want to alter the assembly to suit the location.
You may have to remove a small label on the end of the VTAP reader, to uncover the screw that holds the pieces together. To do this in a way that will keep the label in good condition to reapply later, apply pressure directly down on the label and slide it gently towards the edge of the case.
The case can be changed from an ergonomic desktop reader design to one suited for wall mounting, simply by rotating the PCB and the case front through 180°, keeping the LED and LED window aligned. Mount the PCB in the case, then engage the hooks at the LED window edge of the case to form a hinge, lower the cover and secure with a screw at the opposite end.
The cable can be routed directly out of the back of the reader, if preferred, to hide the wire completely from view or prevent access. The back label includes a circular pre-cut section that can be pushed out to allow the cable to be passed though.