Default Config.txt file
Copy and paste the text from the blue box to your Config.txt file to return to factory default configuration, for a VTAP100‑OEM or VTAP100‑USB‑CC:
!VTAPconfig
VAS1MerchantID=pass.com.pronto.originpass.demo
VAS1KeySlot=6
ST1CollectorID=80644855
ST1KeySlot=6
ST1KeyVersion=1
NFCType2=1
KBLogMode=1
KBSource=A1
KBDelayMS=2
KBPassMode=0
LEDSelect=1
LEDDefaultRGB=1EBBCF
PassLED=00FF00,200,1,1
PassBeep=100,100,2
TagLED=00FF00,200
TagBeep=100
Config.txt variations for other VTAP models:
-
VTAP100‑USB‑SQ is the almost the same, but with LEDSelect=2.
-
VTAP50 models will have LEDSelect=3 to control both external and on-board serial LEDs by default.
Note: Since firmware version v1.1.9.1 all serial communications interfaces are enabled by default, to ensure that serial communications are always possible even if the configuration file config.txt is missing or damaged. To take advantage of this, remove the line ComPortEnable=0.
Copy and paste the text from this box to your Config.txt file to return to factory default configuration, for a VTAP100‑PAC-W-CC:
!VTAPconfig
VAS1MerchantID=pass.com.pronto.originpass.demo
VAS1KeySlot=6
ST1CollectorID=80644855
ST1KeySlot=6
ST1KeyVersion=1
NFCType2=U
MIFAREClassic=U
WiegandMode=1
WiegandSource=A1
WiegandPassMode=1
WiegandPassSeparator=|
WiegandPassSection=2
LEDDefaultRGB=1EBBCF
LEDSelect=1
PassBeep=50,50,2
TagBeep=100,100,1
KBLogMode=0
KBSource=A1
KBDelayMS=2
KBPassMode=0
StartupDelayMS=1000
The factory default configuration for a VTAP100‑PAC-W‑SQ is the almost the same, but with LEDSelect=2.
Copy and paste the text from the blue box to your config.txt file to return your VTAP100‑PRO‑BW reader to Local mode factory default configuration for use with Dot Origin demonstration passses:
!VTAPconfig
VAS1MerchantID=pass.com.pronto.originpass.demo
VAS1KeySlot=6
ST1CollectorID=80644855
ST1KeySlot=6
ST1KeyVersion=1
CloudMode=0
NFCType2=U
KBLogMode=1
KBDelayMS=2
KBPassMode=0
LEDSelect=1
LEDDefaultRGB=1EBBCF
PassBeep=100,100,2
TagBeep=100
PassLED=00FF00,200,1,1
TagLED=00FF00,200
Serial2Settings=115200,n,8,1
BTKeyboardMode=1
Note: It is possible to ‘break’ the VTAP50 and VTAP100 if an incorrect config.txt or file is uploaded, for instance switching off Cloud mode when the reader is intended to work through VTAP Cloud. Contact vtap-support@dotorigin.com if you need Dot Origin to help recover your device.